Ferrous Iron Colorimetric Assay Kit
中文名称:亚铁离子比色法测试盒

Price:
- 样本类型: 血清(浆);动植物组织
- 检测仪器及波长: 酶标仪(590-600 nm,最佳检测波长为593 nm)
- 研究领域: 无机盐离子;植物生理系列;铁死亡
检测原理 |
样本中的亚铁离子与探针结合,生成的物质在593 nm波长处有强吸收峰,在一定范围内其光密度值与亚铁离子浓度成线性相关。
|
灵敏度 | 0.4 μmol/L |
检测范围 | 0.4-50 μmol/L |
精密度 | 批间差:1.5% | 批内差:1.3% |
样本量 | 55 μL(serum/plasma), 300 μL(tissue homogenate) |
检测时间 | 40 min |
检测仪器及波长 | 酶标仪(590-600 nm,最佳检测波长为593 nm) |
保存条件 | 该产品可在 2-8°C避光条件下保存6个月。 |
有效期 | 6个月 |
-
Acteoside ameliorates hepatocyte ferroptosis and hepatic ischemia-reperfusion injury via targeting PCBP2
IF: 14.7Journal: Acta Pharmaceutica Sinica B (2025)Reactivity:MouseSample Type:liver tissue -
FOXO3a-BAP1 axis regulates neuronal ferroptosis in early brain injury after subarachnoid hemorrhage
IF: 10.7Journal: Redox Biology (2025)Reactivity:MouseSample Type:brain tissue -
Lactiplantibacillus plantarum -derived extracellular vesicles alleviate acute lung injury by inhibiting ferroptosis of macrophages
IF: 10.6Journal: JOURNAL OF NANOBIOTECHNOLOGY (2025)Reactivity:MouseSample Type:lung tissue -
Comparative effects of 6PPD and 6PPD-Quinone at environmentally relevant concentrations on hepatotoxicity, glucolipid metabolism and ferroptotic response in adult zebrafish
IF: 7.7Journal: ENVIRONMENTAL RESEARCH (2025)Reactivity:FishSample Type:liver tissue -
TREM2 alleviates sepsis-induced acute lung injury by attenuating ferroptosis via the SHP1/STAT3 pathway
IF: 7.1Journal: FREE RADICAL BIOLOGY AND MEDICINE (2025)Reactivity:MouseSample Type:lung tissue -
Human hair follicle-derived mesenchymal stem cells improve ovarian function in cyclophosphamide-induced POF mice
IF: 7.1Journal: Stem Cell Research & Therapy (2025)Reactivity:MouseSample Type:Serum -
Vitamin D receptor upregulation promotes ferroptosis-related salivary hyposecretion caused by Sod1 knockout in female mice
IF: 7.1Journal: FREE RADICAL BIOLOGY AND MEDICINE (2025)Reactivity:MouseSample Type:submandibular glands (SMGs) tissue -
Role of ferroptosis mediated by abnormal membrane structure in DEHP-induced reproductive injury
IF: 7.1Journal: FREE RADICAL BIOLOGY AND MEDICINE (2025)Reactivity:MouseSample Type:testicular tissue -
Effects of chitosan on restoring spermatogenesis in mice: Insights from gut microbiota and multi-omics analysis
IF: 7.0Journal: FOOD RESEARCH INTERNATIONAL (2025)Reactivity:MouseSample Type:Testicular tissue -
Chlorpyrifos induces spermatogenic dysfunction via ferroptosis in Sertoli cells
IF: 6.9Journal: Genes & Diseases (2025)Reactivity:MouseSample Type:testes tissue
E-BC-K138-F | Reactive Oxygen Species (ROS) Fluorometric Assay Kit (Green) | 96 T |
E-BC-K025-M | Malondialdehyde (MDA) Colorimetric Assay Kit (TBA Method) | 96 T (80 samples) , 48 T (32 samples) |
E-BC-K020-M | Total Superoxide Dismutase (T-SOD) Activity Assay Kit (WST-1 Method) | 96 T (92 samples) , 48 T (44 samples) |
E-BC-K772-M | Total Iron Colorimetric Assay Kit | 96 T (80 samples) , 48 T (32 samples) |
Q1:检测血清样本的时候,出现浑浊可能是什么原因?应该如何调整?
可能是由于样本中的蛋白析出,建议可以增加样本稀释倍数后再测试一下。
Q2:E-BC-K772-M和E-BC-K773-M这两个试剂盒的匀浆介质是一样的吗?可以用同一个试剂处理一份样本后,分别检测总铁和亚铁的含量吗?
这两个试剂盒的匀浆介质是一样的。样本可以用任意一个试剂盒中要求的试剂进行处理,然后分别检测总铁和亚铁的含量,但要注意这两个试剂盒中的其他试剂不要混用。